Measurement parameters Residual chlorine concentration,
PH, temperature
Measurement range Residual chlorine concentration
range: 0-20000 Ppb
PH range: 2-12 PH
Temperature range: -10-110℃
Resolution 0.001
Accuracy Residual chlorine concentration:
±1.0% of Reading;
PH : ±0. 02PH;
Temperature : ±0.1℃
Temperature input Pt1000
Temperature compensation Auto / manual
PH compensation 2-9 PH
Transmitter
Power supply 100-240V AC Frequency50-60Hz
or 20-30V DC
Current output 2 X 0/4-20mA;
Material Polycarbonate
Display screen LCD backlight
Language Chinese or English
Ambient temperature -20-60℃
Relative humidity 0-90%, No condensation
Protection degree IP65
Installation method Wall mounting
Outline dimension 160X188X108mm ( H X W X D )
Sensor
Model CLAse100
Material Glass with316Lstainless steel
Shaft diameter 13mm
Length 120mm
Sampling velocity 50-150ml/min
Process connection 1/4” NPT Inlet / outlet
Cable plug Threaded connector or conjoined
Interface connection Pg13.5s crew thread
Measurement mode Immersion